Bidirectional Oxygenation Valve in the Management of Pulmonary Complications of COVID-19

Purpose

The objective of this study is to determine the safety, feasibility and efficacy of a bidirectional oxygenation Positive End Expiratory Pressure (PEEP) mouthpiece in coronavirus disease 2019 (COVID-19) patients requiring supplemental oxygen by non-rebreather mask.

Condition

  • COVID-19

Eligibility

Eligible Ages
Over 18 Years
Eligible Genders
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • COVID-19 positive - Oxygen saturation <92% - Able to provide informed consent - Receiving oxygen by non-rebreather mask - Not currently requiring intubation

Exclusion Criteria

  • Unable or unwilling to provide informed consent - Cognitive impairment - Rapidly decompensating status requiring urgent or emergent higher level of care

Study Design

Phase
N/A
Study Type
Interventional
Allocation
N/A
Intervention Model
Single Group Assignment
Primary Purpose
Supportive Care
Masking
None (Open Label)

Arm Groups

ArmDescriptionAssigned Intervention
Experimental
Treatment with GO2 PEEP MOUTHPIECE
Participants receiving treatment with the GO2 PEEP MOUTHPIECE
  • Device: GO2 PEEP MOUTHPIECE
    The GO2 PEEP MOUTHPIECE has a bidirectional valve that delivers PEEP with each breath. Participants will be provided a G02 PEEP MOUTHPIECE to use underneath the oxygen face mask and will be instructed to breathe slowly and deeply through the mouthpiece for 15 minutes total. Metrics for primary and secondary endpoints will be recorded immediately prior to use and then at 5, 10 and 15 minutes of use and then 15 minutes after cessation of use.

Recruiting Locations

More Details

NCT ID
NCT04331366
Status
Completed
Sponsor
Emory University

Detailed Description

Severe cases of COVID-19 often mimic the typical course of Adult Respiratory Distress Syndrome (ARDS) and its predictable sequelae. These patients often require intubation and ventilator support in order to sustain adequate oxygenation. Once a COVID-19 patient is intubated, Positive End Expiratory Pressure (PEEP) is a mainstay of treatment and is used in order to improve lung function, treat underlying atelectasis, improve oxygenation, and improve survival. In fact, early clinical data as well as reports from front line physicians treating COVID-19 suggest that PEEP has been the most effective treatment modality. In many cases, PEEP has resulted in improved oxygenation and improved survival. PEEP decreases the propensity for the alveoli to collapse by increasing the air pressure in the lungs. This residual pressure in the lungs at the end of exhalation decreases shunting and allows for more complete gas exchange and improved oxygenation. In patients, PEEP is one of the safest ways to increase partial pressure of oxygen (PaO2) and is used on almost all modern ventilator settings. The GO2 PEEP MOUTHPIECE is a simple, comfortable, and straightforward mouthpiece with a bidirectional valve that effectively delivers PEEP with every breath. Early application of the GO2 PEEP MOUTHPIECE in non-intubated COVID-19 patients may improve outcomes and save lives. Furthermore, this device may allow for less strain on limited resources, especially ventilators. This PEEP mouthpiece could be employed under an oxygen non-rebreather mask to improve oxygenation and avoid intubation.